B95W
Description
86 / 306
5
05_Beschreibung_en.fm - V1.0 - 1.8.17
11
During the stoppage generation:
The working hydraulics are automatically deactivated.
The engine must not be stressed further.
The parking break must remain on.
The direction switch must remain in neutral.
The “exhaust particle filter regeneration” control light is on.
Canceling the stoppage regeneration
Once the stoppage regeneration process has been initiated, it must not be
interrupted (except for in emergencies).
The regeneration process will stop immediately if:
the parking break is released,
the direction switch is no longer in neutral,
the ‘particle filter regeneration’ function is selected again.
End of stoppage regeneration
Once the regeneration process has finished, the engine speed will automatically
reduce to idling speed.
If the regeneration has been successful, the warning buzzer sounds three times once
more and the “particle filter regeneration” control light goes out.
Notice
In an emergency, the operator can cancel the regeneration using the
“exhaust particle filter regeneration” function.
If canceled, the request for regeneration will show again. The
regeneration must then be reauthorized by selecting the ‘particle filter
regeneration’ function.
Notice
The full regeneration process takes an average of 30 minutes,
depending on the filter load
.
Notice
In an emergency, the operator can cancel the regeneration using the
“exhaust particle filter regeneration” function.