EasyManuals Logo

YASKAWA A1000 HHP User Manual

YASKAWA A1000 HHP
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
A.2 Parameter Groups
Parameter
Group
Name Page
Parameter
Group
Name Page
A1 Initialization Parameters 238 H1 Multi-Function Digital Inputs 269
A2 User Parameters 239
H2
<1>
Multi-Function Digital Outputs 273
b1 Operation Mode Selection 240
H3
<1>
Multi-Function Analog Inputs 276
b2
DC Injection Braking and Short Circuit
Braking
241 H4 Multi-Function Analog Outputs 279
b3
<1>
Speed Search 242 H5 MEMOBUS/Modbus Serial Communication 279
b4 Timer Function 243 H6 Pulse Train Input/Output 280
b5 PID Control 243
L1
<1>
Motor Protection 282
b6 Dwell Function 245 L2 Momentary Power Loss Ride-Thru 283
b7 Droop Control 245
L3
<1>
Stall Prevention 284
b8 Energy Saving L4 Speed Detection 285
b9 Zero Servo 246 L5 Fault Restart 286
C1 Acceleration and Deceleration Times 247 L6 Torque Detection 286
C2 S-Curve Characteristics 248 L7 Torque Limit 287
C3
<1>
Slip Compensation 248
L8
<1>
Drive Protection 288
C4 Torque Compensation 249 n1 Hunting Prevention 290
C5 Automatic Speed Regulator (ASR) 250 n2
Speed Feedback Detection Control (AFR)
Tuning
290
C6
<1>
Carrier Frequency 251 n3
High Slip Braking (HSB) and Overexcitation
Braking
290
d2 Frequency Upper/Lower Limits 253 o1 Digital Operator Display Selection 292
d3 Jump Frequency 253 o2 Digital Operator Keypad Functions 292
d4
Frequency Reference Hold and Up/Down 2
Function
254 o3 Copy Function 293
d5 Torque Control 255 o4 Maintenance Monitor Settings 293
d6 Field Weakening and Field Forcing 255 q DriveWorksEZ Parameters 295
d7 Offset Frequency 256 r DriveWorksEZ Connection Parameters 295
E1 V/f Pattern for Motor 1 257 T1 Induction Motor Auto-Tuning 296
E4
<1>
Motor 2 Parameters 260
U1
<1>
Operation Status Monitors 298
F1 PG Speed Control Card (PG-B3/PG-X3) 261 U3 Fault History 302
F2 Analog Input Card (AI-A3) 263
U4
<1>
Maintenance Monitors 302
F3 Digital Input Card (DI-A3) 263 U5 PID Monitors 305
F4 Analog Monitor Card (AO-A3) 263 U6 Operation Status Monitors 305
F5 Digital Output Card (DO-A3) 264 U8 DriveWorksEZ Monitors 306
F6, F7 Communication Option Card 264
<1>
Specifications differ for models CIMR-Ao4A0930, 4A1200 and A1000 HHP.
A.2 Parameter Groups
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
237
A
Parameter List

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 HHP and is the answer not in the manual?

YASKAWA A1000 HHP Specifications

General IconGeneral
SeriesA1000
Overload Capacity150% for 60 seconds
Horsepower0.5-1000 HP
Control MethodV/f Control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Ground Fault
CommunicationModbus, DeviceNet, Profibus, Ethernet/IP
Input Voltage200-240 V, 380-480 V
Output Voltage0-Input Voltage
Frequency400 Hz
Power Range0.4-630 kW
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity5% to 95% RH (non-condensing)
Enclosure RatingIP20, IP00
Voltage200-480 V