EasyManuals Logo

YASKAWA A1000 HHP User Manual

YASKAWA A1000 HHP
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
B.8 Message Examples ...........................................................................................................326
Reading Drive MEMOBUS/Modbus Register Contents .................................................................. 326
Loopback Test................................................................................................................................. 326
Writing to Multiple Registers............................................................................................................ 326
B.9 MEMOBUS/Modbus Data Table........................................................................................328
Command Data ............................................................................................................................... 328
Monitor Data.................................................................................................................................... 329
Broadcast Messages....................................................................................................................... 340
Fault Trace Contents....................................................................................................................... 341
Alarm Register Contents ................................................................................................................. 343
B.10 Enter Command.................................................................................................................344
Enter Command Types ................................................................................................................... 344
Enter Command Settings when Upgrading the Drive...................................................................... 344
B.11 Communication Errors .....................................................................................................345
MEMOBUS/Modbus Error Codes.................................................................................................... 345
Slave Not Responding..................................................................................................................... 345
B.12 Self-Diagnostics ................................................................................................................346
INDEX ................................................................................................................... 347
Table of Contents
8
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 HHP and is the answer not in the manual?

YASKAWA A1000 HHP Specifications

General IconGeneral
SeriesA1000
Overload Capacity150% for 60 seconds
Horsepower0.5-1000 HP
Control MethodV/f Control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Ground Fault
CommunicationModbus, DeviceNet, Profibus, Ethernet/IP
Input Voltage200-240 V, 380-480 V
Output Voltage0-Input Voltage
Frequency400 Hz
Power Range0.4-630 kW
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity5% to 95% RH (non-condensing)
Enclosure RatingIP20, IP00
Voltage200-480 V