Individual Functions
6-87
* If H5-01 is set to zero, then the drive will be unable to respond to Modbus communication.
H5-05
Communicati
on Fault
Detection
Selection
Enables or disables the
communications timeout fault
(CE).
0: Disabled - A communication
loss will not cause a
communication fault.
1: Enabled - If communication is
lost for more than 2 seconds, a
CE fault will occur.
0 or 1 1 No AAAAA
Serial Flt Dtct
H5-06
Drive
Transmit Wait
Time
Set the delay time from when the
Drive receives data to when the
Drive sends data.
5 to 65 5ms No A A A A A
Transmit
WaitTIM
H5-07
RTS Control
Selection
Enables or disables "request to
send" (RTS) control:
0: Disabled - RTS is always on
1: Enabled - RTS turns on only
when sending
0 or 1 1 No AAAAA
RTS Control
Sel
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2