3.9 Control Circuit Wiring
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual 107
Connect control wires as shown in Figure 3.41 to Figure 3.44.
Figure 3.42
Figure 3.41 Terminal Board Wiring Guide (CIMR-UA/UD/UT)
Figure 3.43
Figure 3.42 Terminal Board Wiring Guide (CIMR-UB)
Figure 3.44
Figure 3.43 Terminal Board Location Inside the Drive (CIMR-UB)
Use the space above TB2 to wire TB4 through TB6 as illustrated in Figure 3.44.
Figure 3.45
Figure 3.44 Terminal Board Location Inside the Drive
A – Loosen screw to insert wire.
Wire in the following order:
TB4, TB5, TB6
C – Avoid fraying wire strands when stripping
insulation from wire. Strip length 5.5 mm.
B – Single wire or stranded wire D – Blade depth of 0.4 mm or less
Blade width of 2.5 mm or less
A – Loosen screw to insert wire. C – Avoid fraying wire strands when stripping
insulation from wire. Strip length 5.5 mm.
B – Single wire or stranded wire D – Blade depth of 0.4 mm or less
Blade width of 2.5 mm or less
A
B
TB6 TB5 TB4
C
D
Preparing wire
terminal ends
A
B
C
D
Preparing wire
terminal ends
SIEP_C710636_02B_1_0.book 107 ページ 2015年11月25日 水曜日 午後4時56分