2.2 Mechanical Installation
Mechanical
Installation
2
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual 57
Internal/Flush-Mount
An internal flush-mount requires an installation support set that must be purchased separately. Contact your Yaskawa
representative to order an installation support set and mounting hardware. Figure 2.15 illustrates how to attach the
Installation Support Set A.
1.
Cut an opening in the enclosure panel for the digital operator as shown in Figure 2.16.
2. Mount the digital operator to the installation support.
3. Mount the installation support set and digital operator to the enclosure panel.
Figure 2.14
Figure 2.15 Internal/Flush Mount Installation
Note: Use a gasket between the enclosure panel and the digital operator in environments with a significant amount of dust or other
airborne debris.
Figure 2.15
Figure 2.16 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)
Enclosure panel
Unit: mm
Digital Operator
Installation Support Set A
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)
M3 × 6
Phillips recessed
pan head machine screw × 2
120
45
59
+0.5
0
89
+0.5
0
Unit: mm