EasyManua.ls Logo

YASKAWA YRC1000 - Spot Supervision Window Setting

YASKAWA YRC1000
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Spot Welding Application Using a Motor Gun
1.12 Tip Wear Detection and Wear Compensation (Motor Gun)
1-116
1.12.3 Spot Supervision Window Setting
Shows the tip wear amount, etc.
Also, the wear amount detection relevant settings can be performed.
Spot supervision window
1. GUN NO.
Shows the gun No.
Select the No. by pressing [PAGE].
2. WELD COUNT
(CURRENT, TOLERANCE, SETTING(OUT#))
The numbers that the welding instruction (SVSPOT, SVSPOTMOV) is
performed is indicated to {CURRENT} as the present value.
Also, the universal output signal specified at {SETTING (OUT#)} is
turned ON when a value in {CURRENT} has exceeded a value in {TOL-
ERANCE}.
3. RESET COUNT
The value at {WELD COUNT (CURRENT)} can be cleared when the
signal specified to {RESET COUNT} is turned ON.
4. WEAR (M) (CURRENT, TOLERANCE, SETTING(OUT#))
Present wear amount at the movable side tip is indicated.
The value is updated when the wear detection is finished.
Also, the universal output signal specified at {SETTING (OUT#)} is
turned ON when the value in {CURRENT} has exceeded the value in
{TOLERANCE}.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
126 of 198

Table of Contents

Other manuals for YASKAWA YRC1000

Related product manuals