1 Spot Welding Application Using a Motor Gun
1.13 Other Functions Using a Motor Gun
1-160
1.13.7 Welding Conditions Group Output Function
1.13.7.1 Operation Flow Chart
With the welding conditions group output function, a group signal is output
to the welder during welding.
The following shows the operation flow chart for the welding conditions
group output function.
1.13.7.2 Procedure for Assigning the Group Output Signal
The following describes how to assign the signal number for group output
when executing the SVSPOT/SVSPOTMOV instruction.
1. Select {SPOT WELDING} on the {Main Menu}.
2. Select {WELDER IF}.
Start
End
Set the group output tag
Assign the universal signal
for the group output