1 Spot Welding Application Using a Motor Gun
1.13 Other Functions Using a Motor Gun
1-141
<When the Gun ID No. signal start with IN10, and the Gun ID No. signal
end with IN12:>
The signals listed in the table above are confirmed when the YRC1000
control power supply is turned ON.
If the signal status indicates that the gun is connected when YRC1000
controller is turned ON, the servo power supply for the gun motor turns
ON when the servo is turned ON.
If the signal status indicates that the gun is not connected when YRC1000
controller is turned ON, the servo power supply for the robot motor turns
ON when the servo is turned ON, but the servo power supply for the gun
motor is not turned ON.
Gun No. IN10 IN11 IN12
GUN# (1) ON OFF OFF
GUN# (2) OFF ON OFF
GUN# (3) ON ON OFF
GUN# (4) OFF OFF ON
GUN# (5) ON OFF ON
GUN# (6) OFF ON ON
151 of 198