1 Spot Welding Application Using a Motor Gun
1.3 Setting of Motor Gun
1-17
7. Select “OK”.
A message “The false detection of touch may occur by friction
torque of motor gun. Check the factor of high friction torque.”
appears.
If no failure is found to the gun, set the touch pressure a higher
value than the value of friction torque value. Then, start the MOTOR
GUN AUTO TUNING operation from the step 4 again. For the
setting of touch pressure, refer to chapter 1.4.6 "Gun Detail
Setting File".
8. Select “REGIST”.
{STATUS} on the window changes from {INCOMPLETE} to
{COMPLETE}. The date is registered to {ENFORCEMENT DAY}.
If “CANCEL” is selected, the MOTOR GUN AUTO TUNING
operation does not complete.