1 Spot Welding Application Using a Motor Gun
1.4 System Setting (Motor Gun)
1-32
8. WELD COND OUTPUT TIME
When the WELD COND OUTPUT TYPE is “PULSE” or “START SIG-
NAL”, the welding condition signals are turned ON for the time specified
at this item.
Refer to Welder Start Timing .
9. WELD COND MAX NUM
Set the maximum number of the welding condition.
If the greater value than this setting is set as the WELDING CONDI-
TION (WTM tag) the value will not be outputted through the welding
condition signals.
10. WELDING CONDITION PARITY
The parity signal for the WELDING CONDITION.
When executing the welding instruction (SVSPOT, SVSPOTMOV) or
the manual spot, the value of WELDING CONDITION PARITY and
WELDIG CONDITION are outputted at the same time.
Settings of the odd/even number parity is performed using the parame-
ter. (For the details, refer to “ YRC1000 GENERAL OPERATOR’S
MANUAL (RE-CSO-A051) 8.10.3.4 AxP006: PARITY SPECIFICATION
FOR WELDING CONDITIONS”.)
11. WELDING COMMAND
The welding command signal to the welder.
This signal is output when executing the welding instruction (SVSPOT,
SVSPOTMOV) or the manual spot.
Setting is unnecessary when WELD CONDITION functions as wellder
start instruction.
12. WELD GROUP OUTPUT
The weld group output signal for the welder.
The set welding group output No. (set at WGO tag) is outputted through
the setting signal in this item when executing the welding instruction
(SVSPOT, SVSPOTMOV) or the manual spot.
Refer to chapter 1.13.7 "Welding Conditions Group Output Function".
13. STICK DETECT DELAY TIME
Set the sticking detect delay time.
An alarm occurs if the gun does not open for more than the setting time
because the gun has stuck when execute the welding instruction
(SVSPOT, SVSPOTMOV) or the manual spot.
Be sure that the allocated user signals are not used in the
any JOBs. If the same signals are used in the JOBs, mal-
functions will result.