EasyManua.ls Logo

YOKOGAWA PT500 - 2. Change the Min. rudder angle for alarm detection of the variation angle; 3. Change the Max. rudder angle for alarm detection of the variation angle

YOKOGAWA PT500
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19-2
SM80B22M02E
1. Change the item.
(1)Press the
ENTER
ENTERENTER
ENTER
key after displayed "
Option Set 1…
" on the data display.
Data display becomes setting mode of Servo loop failure alarm.
Change the setting mode by using the
+
++
+
or
-
--
-
Key
①⇔②⇔③⇔④⇔⑤⇔⑥⇔⑦⇔⑧⇔⑨⇔⑩⇔①
Press
ENTER
ENTERENTER
ENTER
key to select the setting item.
2Change the Min. rudder angle for alarm detection of the variation angle
Set the Min. rudder angle for alarm detection of the variation angle
(1)Press the
ENTER
ENTERENTER
ENTER
key after displayed "
Min.Angle= # #ˆ
" on the data display.
Data display become under setting mode.
Setting range: from 2 to 10
(Initial value is set 5 degrees)
Press
+
++
+
or
-
--
-
key to alter the Min. rudder angle for alarm detection of the variation
angle.
Press
ENTE
ENTEENTE
ENTER
RR
R
key to set the Min. rudder angle..
3.Change the Max. rudder angle for alarm detection of the variation angle
( For normal rudder angle:P/S Max.rudder order from 35 to 45degrees.)
(1)Press the
ENTER
ENTERENTER
ENTER
key after displayed "
Max.AngleN= # #ˆ
"
on the data display.
Data display become under setting mode.
Setting range: from 70 to 90
(Initial value is set 70 degrees)
Press
+
++
+
or
-
--
-
key to alter the Max. rudder angle for alarm detection of the variation
Servo Loop Err.
Min.Angle< ##ˆ
Servo Loop Err.
Max.AngleN< ##ˆ
Servo Loop Err.
Max.TimeSW= ###s
Servo Loop Err.
<EXIT>
Servo Loop Err.
Min.Angle= # #ˆ
Servo Loop Err.
Min.TimeS= ##s
Servo Loop Err.
Max.AngleN= #
Servo Loop Err.
Max.TimePW= ##s
Servo Loop Err.
Max.AngleW= ###ˆ
Servo Loop Err.
Max.Time PW= ###s
Servo Loop Err.
Max.TimeSN= ##s
Servo Loop Err.
Min.TimeP= ##s