Administrator Console 4 - 35
Connect Status - Indicates whether the reader is connected to the LLRP host. This button toggles
between ConnectLLRP and DisconnectLLRP. Clicking ConnectLLRP initiates an LLRP connection to
the host server.
LLRP configuration options when the reader is in Secure mode:
Security Mode - Specifies whether LLRP communicates in secure or unsecure mode. Checking Enable
Secure Mode switches the LLRP port to 5085 by default. You can override the port value. LLRP in
secure mode supports ciphers that are compliant with TLS1.2.
Validate Peer - Specifies whether the validation of peer against the same certification authority issued
certificate is required. If you select the validate peer option, the secure LLRP service on the reader
allows connection for valid secure peer entities only if the certificate of the peer is issued from the same
certification authority that issued the certificate for the reader. By default the reader uses self-signed
certificates, and peer certificate based validation is disabled.
SNMP Settings
Select SNMP to view the Configure SNMP Settings window.
Figure 4-24
Configure SNMP Settings Window
Use this window to configure the SNMP host settings to allow sending network status events and receiving
network status event notifications:
Send SNMP Trap To - Configures the host IP address to which the SNMP trap is sent. Leave this blank to
send no traps to any host.
SNMP Community String - SNMP community string to use for SNMP set and get.
SNMP Version - SNMP version to use in the reader. Supported versions are V1 and V2c.
Send Server Heartbeat - Sends a heartbeat message periodically to the configured SNMP host.
NOTE Send SNMP Trap To and Send Server Heartbeat take effect immediately after clicking Set Properties.
However, perform a Commit to persist the changes. The modified SNMP Community String and SNMP
Version are not affected until the reader reboots.

Table of Contents

Other manuals for Zebra FX7500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra FX7500 and is the answer not in the manual?

Zebra FX7500 Specifications

General IconGeneral
InterfaceUSB
Product colorWhite
LED indicatorsActivity, Power, Status
Housing materialAluminium, Metal, Plastic
Battery type-
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 55 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84719000
Weight and Dimensions IconWeight and Dimensions
Depth43.2 mm
Width149.9 mm
Height195.6 mm
Weight860 g

Related product manuals