284 Parameters
0.0 … 6400.0 A Nominal current of the motor. The allowable range is 1/6…2
× I
max
of the drive (0…2 × I
max
with scalar control mode).
10 = 1 A
99.07 Mot nom voltage Defines the nominal motor voltage as fundamental phase-to-
phase rms voltage supplied to the motor at the nominal
operating point. This setting must match the value on the
rating plate of the motor.
Notes:
• The stress on the motor insulation is always dependent
on the drive supply voltage. This also applies to the case
where the motor voltage rating is lower than that of the
drive and the supply.
• This parameter cannot be changed while the drive is
running.
1/6 … 2 × U
N
Nominal voltage of the motor. 10 = 1 V
99.08 Mot nom freq Defines the nominal motor frequency.
Note: This parameter cannot be changed while the drive is
running.
5.0 … 500.0 Hz Nominal frequency of the motor. 10 = 1 Hz
99.09 Mot nom speed Defines the nominal motor speed. The setting must match
the value on the rating plate of the motor.
Notes:
• For safety reasons, after ID run, the maximum and
minimum speed limits (parameters 16.17 and 16.17) are
automatically set to 1.2 times the value of this parameter.
• This parameter cannot be changed while the drive is
running.
0 … 30000 rpm Nominal speed of the motor. 1 = 1 rpm
99.10 Mot nom power Defines the nominal motor power. The setting must match
the value on the rating plate of the motor. If multiple motors
are connected to the drive, enter the total power of the
motors.
The unit is selected by parameter 16.17 Power unit.
Note: This parameter cannot be changed while the drive is
running.
0.00 … 10000.00
kW
Nominal power of the motor. 100 = 1 kW
99.11 Mot nom cosfii Defines the cosphi of the motor for a more accurate motor
model. Not obligatory; if set, should match the value on the
rating plate of the motor.
Note: This parameter cannot be changed while the drive is
running.
0.00 … 1.00 Cosphi of the motor. 100 = 1
99.12 Mot nom torque Defines the nominal motor shaft torque for a more accurate
motor model. Not obligatory.
Note: This parameter cannot be changed while the drive is
running.
0 … 2147483.647
Nm
Nominal motor torque. 1000 = 1 N•m