124 Parameters
04.21 Act val 2 out Actual value 2 (selected by parameter 28.03 Act val 2 src). 100 = 1 unit
04.22 Act val % Final actual value in %. 100 = 1%
04.23 Setpoint val 1 Setpoint 1 (selected by parameter 29.02 Setpoint 1 src). 100 = 1 unit
04.24 Setpoint val 2 Setpoint 2 (selected by parameter 29.03 Setpoint 2 src). 100 = 1 unit
04.25 Setpoint val % Final setpoint in %. 100 = 1%
04.26 Wake up level Final calculated wake-up level. See the selections of
parameter 77.08 Wake up mode sel.
100 = 1
04.27 Shared source Node number of the drive that is currently the source of
shared signals. See parameters 76.1176.16.
TBA
04.28 Pump runtime Pump run-time counter. The counter runs when the drive is
running (started). Can be reset using parameter 78.14
Runtime change.
1 = 1 h
04.29 Trad 1 runtime Pump 1 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.30 Trad 2 runtime Pump 2 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.31 Trad 3 runtime Pump 3 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.32 Trad 4 runtime Pump 4 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.33 Trad 5 runtime Pump 5 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.34 Trad 6 runtime Pump 6 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.35 Trad 7 runtime Pump 7 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
04.36 Trad 8 runtime Pump 8 run-time counter (for traditional control – see page
94). Can be reset using parameter 78.14 Runtime change.
1 = 1 h
05
05 Pump values
Pump station actual values.
05.01 MF status State of drive in a multipump configuration (several drives
connected by the drive-to-drive link).
No Drive-to-drive communication is not active. 0
Standby The drive is ready to start and waiting for a start command
from the master.
1
Master The drive is running and currently the master. 2
Follower The drive is running and currently a follower. 3