286 Parameters
Reduced Reduced ID Run. This mode should be selected instead of
the Normal ID Run if
• mechanical losses are higher than 20% (i.e. the motor
cannot be de-coupled from the driven equipment), or if
• flux reduction is not allowed while the motor is running
(i.e. in case of a motor with an integrated brake supplied
from the motor terminals).
With Reduced ID run, the control in the field weakening area
or at high torques is not necessarily as accurate as with the
Normal ID run. Reduced ID run is completed faster than the
Normal ID Run (< 90 seconds).
Note: Check the direction of rotation of the motor before
starting the ID run. During the run, the motor will rotate in the
forward direction.
WARNING! The motor will run at up to approximately
50…100% of the nominal speed during the ID run.
ENSURE THAT IT IS SAFE TO RUN THE MOTOR
BEFORE PERFORMING THE ID RUN!
2
Standstill Standstill ID run. The motor is injected with DC current. The
motor shaft will not rotate.
Note: This mode should be selected only if the Normal or
Reduced ID run is not possible due to the restrictions caused
by the connected mechanics (e.g. with lift or crane
applications).
3
Autophasing Reserved. 4
Cur meas cal Current offset and gain measurement calibration. The
calibration will be performed at next start.
5
No. Name/Value Description FbEq