Connecting the axis-5 joint unit cabling
NoteAction
xx2000002138
Reconnect the connectors to the drive board.
D4/5.X1 to X1
D5.DC+ to +DC
D5.DC- to Ground
D4/5.X4 to X4
D5/4.X2 to X2
D4/5.X5 to X5
1
xx2000002137
Connect the connectors to each other and snap
them to the cable holders.
J5/6.DC+ to J6.DC+
J5/6.DC- to J6.DC-
J5/6.CS to J6.CS
J5/6.CP to J6.CP
2
Hex socket head cap screw: M3x6 (1
pcs).
Secure the cables for functional earth and
protective earth with a screw.
3
Tightening torque: 0.8 Nm.
xx2000002136
Continues on next page
1008 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued