5.3.6 Replacing the axis-5 cabling
Location of the cable harness
The cable harness is located as shown in the figure.
xx2100000061
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
1 Remove the tubular cover.
2 Separate the cabling between the tubular and the tilt (at the axis-4 joint unit).
3 Remove the tilt and place on a workbench.
4 Remove the axis-6 joint unit.
5 Remove the axis-5 cover.
6 Remove the axis-5 joint unit.
7 Replace the cabling.
Continues on next page