4.4 Cleaning activities
4.4.1 Cleaning the CRB 15000
General
Different cleaning methods are allowed depending on the type of protection of the
CRB 15000.
Note
Always verify the protection type of the robot before cleaning.
WARNING
Turn off all electrical power supplies to the robot before starting the cleaning.
Special cleaning considerations
This section specifies some special considerations when cleaning the robot.
Always use cleaning equipment as specified. Any other cleaning equipment
may shorten the life of the robot.
Always check that all protective covers are fitted to the robot before cleaning.
Do not use compressed air to clean the robot.
Do not use solvents that are not approved by ABB to clean the robot.
Do not remove any covers or other protective devices before cleaning the
robot.
Cleaning methods
This following table defines what cleaning methods are allowed for ABB
manipulators depending on the protection type.
Cleaning methodProtection
type
High pressure water,
steam or spray
Rinse with waterWipe with clothVacuum
cleaner
NoNoYes. With light
cleaning deter-
gent.
YesStandard
Usable detergents
This table specifies approved light cleaning detergents according to methods in
the table Cleaning methods on page 195.
ConcentrationDetergent
i
70%Isopropyl Alcohol
75%, 99.7%Ethanol
i
The manipulator can be cleaned (wiped with cloth) occasionally with specified detergents. Long
term use may lead to surface/apperance deterioration.
Product manual - CRB 15000 195
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.