NoteAction
xx2000002010
Snap loose and disconnect the connectors:
J1.DC+
J1.DC-
J1.CS
J1.CP
3
xx2000002009
Disconnect the connectors from the drive board.
D1.X1 from X1
D1.DC+ from DC+
D1.DC- from ground
D1.X4 from X4
D1.X2 from X2
D1.X5 from X5
DR.X8 from X8
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
Removing the joint cable
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 53.
1
Continues on next page
Product manual - CRB 15000 251
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the axis-1 cabling
Continued