Closing the housing top cover
NoteAction
Gasket: 3HAC075056-001Check the inner plate gasket.1
xx2000002095
Replace if damaged.
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Refit the inner plate with the screws.2
Tightening torque: 1.4 Nm
xx2000002076
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Refit the cover with the four screws.3
Tightening torque: 0.45 Nm
xx2000002075
Continues on next page
Product manual - CRB 15000 411
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.5 Replacing the axis-4 cabling
Continued

Table of Contents

Related product manuals