EasyManua.ls Logo

ABB CRB 15000 - Page 432

ABB CRB 15000
1096 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disconnecting the axis-5 joint unit cabling
NoteAction
xx2000002135
Cut the cable ties.1
xx2000002136
Remove the functional and protective earth cables
by removing the screw.
2
xx2000002137
Snap loose and disconnect the connectors:
J5/6.DC+
J5/6.DC-
J5/6.CS
J5/6.CP
3
TweezersDisconnect the connectors from the drive board.
D4/5.X1
D5.DC+
D5.DC-
D4/5.X4
D5.X2
D4/5.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
xx2000002138
Continues on next page
432 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.6 Replacing the axis-5 cabling
Continued

Table of Contents

Related product manuals