NoteAction
xx2100001449
Remove the screws and washers.2
xx2100001450
Insert two M4 screws to the pressed out holes
and press out the stainless shaft.
3
xx2100001451
Flange tightening tool:
3HAC079686-001
xx2100001452
Place the flange tightening tool together with a
3/8" (10 mm) socket spanner on the seal ring unit
and loosen the unit.
4
xx2100001453
Remove the gasket and seal ring unit.5
Continues on next page
146 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.4.2 Replacing the sealing set on tool flange of Hygienic robots
Continued