NoteAction
Sikaflex 521FC skin dry time: 10
minutes
Wait for the sealant to dry and then remove the
mask.
4
Trans Clear skin dry time: 40
minutes
For robots with protection type
Clean Room
Apply a little sealant to the inner surface of the
swing sealing plug.
5
For robots with food grade lubric-
ation
Sealant, Sikaflex 521FC
For robots with protection type
Hygienic
Sealant, Trans Clear
xx1600000211
xx1600000261
xx1600000212
Refit the swing sealing plug.6
xx1600000213
If there is any overflowing sealant, remove and
clean it.
Make sure no space exists between the swing
sealing plug and the robot casting, and the sealant
string is fully jointed with the plug.
7
168 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.2.4 Swing sealing plug for Clean Room, food grade lubrication and Hygienic robots
Continued