NoteAction
xx1300002434
Reconnect the motor connectors.
R2.ME2
R2.MP2
12
Tightening torque: 1.5 Nm.
xx1400000021
Refit the axis-2 motor bracket to the cable pack-
age with the two screws.
CAUTION
Do not loosen the cable clamp screw! There is a
risk of rearrangement of the cable layout which
would result in shortened lifetime of the cable
harness.
13
xx1300002432
Refit the axis-2 motor bracket to the motor.14