NoteAction
xx1300002399
Disconnect the remaining FPC connectors.7
Removing the housing extender unit
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 158.
2
xx1300002373
Remove the axis-4 FPC unit screws.3
xx1600000262
For robots with protection type Foundry Plus
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Remove the plugs covering the extender unit
screws with a needle-nose plier.
4