NoteAction
xx1300002432
Remove the axis-2 motor bracket screws.6
xx1300002434
Disconnect the motor connectors.
• R2.ME2
• R2.MP2
7
xx1300002548
Pull out the cable harness slightly from the
lower arm housing.
Note
The cabling is still connected inside the
robot, so be careful not to strain the cables!
8
Continues on next page
648 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.2 Replacing the axis-2 drive unit