Connecting the air hoses and CP/CS cabling (if equipped)
Notice that the procedure differs depending on the protection class and protection
type.
Connecting the air hoses and CP/CS cabling on robots not in protection type Hygienic
Use this procedure if the robot is not in protection type Hygienic.
NoteAction
For robots with protection type Clean Room1
For robots with food grade lubrication
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Air connector set with Ethernet
hole in flange: 3HAC049664-001
Reconnect the air hoses.
Replace the air hose connector set if damaged.
2
Air connector set without Ethernet
hole in flange: 3HAC049665-001
xx1400000738
xx1500000252
If equipped, reconnect the CP/CS connector.
For robots with protection class IP67
For robots with protection type Foundry Plus
1 Check the gasket.
2 Replace if damaged.
For robots with protection type Clean Room
For robots with food grade lubrication
1 Remove residual locking liquid and other
pollutants with cleaning agent Loctite 7063.
2 Apply flange sealing Loctite 574 on the
mounting surfaces of the CP/CS connector
and wipe clean if there is any overflowing
Loctite 574.
3
On robots with protection class
IP67
On robots with protection type
Foundry Plus
Gasket: 3HAC058567-001
xx1500000251
Continues on next page
Product manual - IRB 1200 751
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.6 Replacing the axis-4 timing belt
Continued