NoteAction
All mechanical units connected to the system are
shown with their calibration status.
2
Tap the mechanical unit in question.
Note
For RobotWare 7, the mechanical unit page is
displayed only if there is more than one mechan-
ical unit available.
The FlexPendant will give all inform-
ation needed to proceed with Axis
Calibration.
The calibration method used at ABB factory for
each axis is shown, as well as calibration method
used for the robot during last field calibration.
3
Valid for RobotWare 64
Tap Call Calibration Method. The software will
automatically call for the procedure for the valid
calibration method. If not, tap Call Routine and
then tap Axis calibration.
Valid for RobotWare 75
Tap Calibration Methods on the right pane and
then tap Calibration. The software will automatic-
ally call for the procedure for the valid calibration
method.
A brief overview of the sequence
that will be run on the FlexPendant
is given in Overview of the calibra-
tion procedure on the FlexPendant
on page 826.
Follow the instructions given on the FlexPendant.6
Fitting of calibration tools
The figures show the calibration tools in contact with each other on each axis.
The position of the complete robot shown for each axis is only an example.
In order for the axis to be able to be moved to calibration position, or in order for
getting proper access to the calibration bushing, other axes might need to be
jogged to positions different from 0 degrees. Information about which axes are
Continues on next page
828 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued