NoteAction
CAUTION
The gearbox can contain an excess of pressure
that can be hazardous. Open the oil plug care-
fully in order to let out the excess pressure.
3
xx1800001136
Valid for IRB 2600 Type C-20/1.65, IRB 2600
Type C-12/1.65:
Remove the protective cap from the oil nipple
and connect the oil dispenser.
4
xx1800001137
Valid for IRB 2600 Type C-20/1.65, IRB 2600
Type C-12/1.65:
Remove the plug from the vent hole.
Note
The vent hole is opened to let out air during the
filling process.
5
Different position due to design differ-
ences:
xx1800001137
Valid for IRB 2600-20/1.65, IRB 2600-12/1.65,
IRB 2600-12/1.85, IRB 2600ID-15/1.85, IRB
2600ID-8/2.0:
Open the oil plug, filling.
6
xx1800001139
Continues on next page
156 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing the oil, axis 1 gearbox on floor mounted robots
Continued