EasyManuals Logo

ABB IRB 2600 Series User Manual

ABB IRB 2600 Series
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #185 background imageLoading...
Page #185 background image
Cleaning methods
The following table defines what cleaning methods are allowed depending on the
protection type.
Note
Rinsing with water is not allowed for a robot with integrated dressing (ID variants).
Cleaning methodProtection
type
High pressure water or
steam
Rinse with water
i
Wipe with clothVacuum
cleaner
NoYes. It is highly re-
commended that
the water contains
a rust-prevention
solution and that
the manipulator is
dried afterwards.
Yes. With light
cleaning deter-
gent.
YesStandard
Yes
ii
.Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution.
Yes. With light
cleaning deter-
gent or spirit.
YesFoundry Plus
It is highly recommended
that the water and steam
contains rust preventive,
without cleaning deter-
gents.
i
Rinsing with water is not allowed for a robot with integrated dressing (ID variants)!
ii
Perform according to section Cleaning with water and steam on page 185.
Cleaning with water and steam
Instructions for rinsing with water
ABB robots with protection types Standard, Foundry Plus, Wash, or Foundry Prime
can be cleaned by rinsing with water (water cleaner).
1
The following list defines the prerequisites:
Maximum water pressure at the nozzle: 700 kN/m
2
(7 bar)
I
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
I
I
Typical tap water pressure and flow
Instructions for steam or high pressure water cleaning
ABB robots with protection types Foundry Plus, Wash, or Foundry Prime can be
cleaned using a steam cleaner or high pressure water cleaner.
2
The following list defines the prerequisites:
Maximum water pressure at the nozzle: 2500 kN/m
2
(25 bar)
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum water temperature: 80° C
1
See Cleaning methods on page 185 for exceptions.
2
See Cleaning methods on page 185 for exceptions.
Continues on next page
Product manual - IRB 2600 185
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
3 Maintenance
3.5.1 Cleaning the IRB 2600/IRB 2600 ID
Continued

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 2600 Series and is the answer not in the manual?

ABB IRB 2600 Series Specifications

General IconGeneral
Number of Axes6
Robot ControlIRC5
Mountingwall
ProtectionIP67
Max SpeedAxis 1: 180°/s
Reach1.65 m / 1.85 m

Related product manuals