NoteAction
A
B
xx0800000389
Only applicable to axis-3, axis-4, axis-5 and
axis-6 motors!
Remove the cover in the back of the arm house.
WARNING
The robot must never be run without the cover
in the armhouse fitted! It is a vital supporting
part of the robot.
5
Parts:
A: Cover
B: Attachment screws (8 pcs) +
washers.
How to remove the fan is detailed in
section:
Installation of cooling fan for
motors (option) on page 93
Only applicable to motors on axes 1 and 2
with fan fitted!
Remove the fan before starting the removal!
6
See the figure in:
Location of axis-1 and axis-2
motors on page 301
Only applicable to axis-1 and axis-2 motors!
Remove the motor cover.
7
See the figure in:
Location of axis-1 and axis-2
motors on page 301
Only applicable to axis-1 and axis-2 motors!
Remove the cable gland cover.
8
See the figure in:
Location of axis-1 and axis-2
motors on page 301
Only applicable to axis-1 and axis-2 motors!
Remove the connection box.
Note
Only needed if the motor shall be replaced with
a new one.
9
Note
When removing motors 4,5 or 6 the
cables of motor axis 3 must be discon-
nected too. This must be done in order
to be able to remove the bracket on
top of motors axes 4, 5 and 6.
Disconnect the motor cables.10