Loading...
NoteAction
xx2100002059
Open the oil plug.4
Option Inverted (3317-1)
xx2100002061
Check the oil level.5
Required oil level is: 0-10 mm below oil plug
hole (floor-mounted robot).
Required oil level is: 0-10 mm below oil plug
hole (inverted robot).
Type of oil and total amount is detailed
in Technical reference manual - Lubric-
ation in gearboxes.
Add or drain oil, if required.6
Further information about how to drain
or fill with oil is found in section Chan-
ging the oil in axis-2 gearbox on
page 154.
Continues on next page
Product manual - IRB 5720 125
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
4 Maintenance
4.3.7 Inspecting the oil level in axis-2 gearbox
Continued