Refitting the cable harness in the base
NoteAction
xx2100001216
Run the cables through the protection tube.1
xx1300000736
Make sure that the cables are not
twisted. Each cable must be in line
with its position on the base plate.
Make sure that the R1.SMB cable
will run on the correct side of the
R1.MP1, see the figure.
2
Make sure that the markings on the cables
are facing the base cover, when connected.
3
Screw dimension for R1.MP: M6x25 A2-70Connect connectors R1.MP and R1.SMB.4
Tightening torque for R1.MP: 10 Nm.
Tightening torque for R1.SMB: 10 Nm.
xx2100001109
Continues on next page
Product manual - IRB 5720 285
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7.2 Refitting the cable harness
Continued