Connectors
Connectors on C line/ V line controllers
4
1
5
6
7
3
2
WAN LAN MGMT
I/O
ETHERNET SWITCH
ABB Ability™
HMI
xx2100002082
DescriptionC line controller label
ABB Scalable I/O. Connected to the control-
ler's Private Network. Intended for chaining
more ABB Scalable I/O units.
I/O1
Connected to the controller's Private Net-
work. Intended for connecting ABB Scalable
I/O units and network based process equip-
ment local to the controller.
ETHERNET SWITCH2
Intended for connecting the controller to in-
ternet/ABB Ability™.
ABB Ability™3
Connected to the controller's Public Network.
Intended for connecting the robot controller
to a factory wide industrial network.
WAN4
Connected to the controller's I/O Network.
Intended for connecting the robot controller
to a factory wide industrial network isolated
from WAN.
LAN5
Connected to the controller's Private Net-
work. The MGMT port shall be used by ser-
vice personnel in close proximity to the con-
troller, with a single client connected to the
controller.
MGMT (Management)6
Note
The management port shall never be used
for more than one client at a time. ABB Robot-
ics assumes no responsibility for any er-
rors/hazards that may appear when more
than one client is used.
Specific connector for connecting the Flex-
Pendant.
HMI (FlexPendant)7
Continues on next page
Product manual - OmniCore C30 105
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore
Continued

Table of Contents