3.5.5 Connecting power supply to and grounding the controller
Note
How to manufacture a cable with connector is described in section Fitting the
connector on page 92.
DANGER
A residual current device (RCD) must be installed.
Location of power supply connection
A
xx1700001060
Power inlet connector, X0A
Note
According to IEC60204-1, the power-operated switch should be installed between
600 mm to 1,900 mm above the servicing level. The switch will be easily
accessible.
Location of grounding point
Note
The whole cabinet ground is connected to the X0.PE point.