3.5.4 Fitting the connector
General
This section describes how to manufacture a cable for connecting the main power
to the controller.
xx1700000742
Detailed view
xx1900000058
Description
GlandA
Crown clampB
Shielding elementC
Distance sleeveD
Contact socketE
Insulation insertsF
HousingG
Specifications
The following describes the cable requirements for the main power connection to
the OmniCore C30 controller.
DescriptionComponent
Flexible oil resistant rubberCable type
3C x 1.5 mm
2
or AWG14Cable area
Continues on next page