Note/IllustrationAction
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800001188
Cable clipA
Secure the optional power supply with
the screws.
3
Connect:
• A1.X7 - T5.X1
Note
The connector on the AC_in cable
(3HAC061099-001) is fastened to the
cable clip in the illustration when the
power supply optional is not selected.
4
Refitting the axis computer to the frame
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Reconnect and secure the screw:
• K6.X4, K6.X5 - SMB.
3
Continues on next page
164 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.4 Installing the power supply optional device and the harness 24 V extension
Continued