Removing the power supply baseline
Note/IllustrationAction
Disconnect:
• T2.X1 - A1.X6
• T2.X2 - K2.X1
1
xx1800000547
Remove the screws and the power sup-
ply.
2
Refitting the power supply baseline
Refitting the power supply
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Continues on next page
Product manual - OmniCore C30 367
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.11 Replacing the power supply
Continued