NoteAction
LED PS should be green.
If not, see Troubleshooting
the power supply on
page 550.
If the power supply is ok,
see Troubleshooting the
power unit on page 532.
If the power unit is ok, check
that the power inlet is prop-
erly connected and the
power inlet switch is turned
on.
For more details about the LEDs,
see Troubleshooting the robot sig-
nal exchange proxy on page 555.
Look at the LED PS.2
LED MS should be green.
If not, see Troubleshooting
the robot signal exchange
proxy on page 555.
Look at the LED MS.3
LED PC and LED HMI should be
green.
If not, see Troubleshooting
the robot signal exchange
proxy on page 555
Look at the LEDs PC and HMI.4
For more details about the LEDs,
see Troubleshooting the main
computer on page 547.
Look at the LEDs PC PWR, PC HDD, and PC
STAT.
5
If the problem remains, contact ABB.6
Tip
For more details, see Circuit diagram - OmniCore C30, Circuit diagram - OmniCore
C30 for IRB 14050, Circuit diagram - OmniCore C30 for CRB 15000.