NoteAction
If any connection fails, re-
pair the connection and go
to step six.
If the connections are ok, go
to the next step.
Check that the connection from the robot signal
exchange proxy to the main computer is ok:
K2.X8 - A2.X6
K2.X2 - A2.X1
K2.X12 - A2.K3.X6,7
K2.X3 - A2.K3.X1
6
If possible, test by connecting another FlexPend-
ant. This is to eliminate the FlexPendant and cable
as error sources; Test the FlexPendant with a
different controller to eliminate the controller as
error source.
7
If it is not ok, contact your local
ABB.
Check that the FlexPendant works normally.
Tip
This is detailed in section Troubleshooting the
FlexPendant on page 529.
8
Product manual - OmniCore C30 521
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.2.5 Problem starting or connecting the FlexPendant
Continued