NoteAction
• If any connection fails, re-
pair the connection and go
to step six.
• If the connections are ok, go
to the next step.
Check that the connection from the robot signal
exchange proxy to the main computer is ok:
• K2.X8 - A2.X6
• K2.X2 - A2.X1
• K2.X12 - A2.K3.X6,7
• K2.X3 - A2.K3.X1
6
If possible, test by connecting another FlexPend-
ant. This is to eliminate the FlexPendant and cable
as error sources; Test the FlexPendant with a
different controller to eliminate the controller as
error source.
7
If it is not ok, contact your local
ABB.
Check that the FlexPendant works normally.
Tip
This is detailed in section Troubleshooting the
FlexPendant on page 529.