Reference on
the circuit dia-
gram
LabelDescription
K5.1I/OScalable I/O connectionE
K2-X14, K2-X15,
K2-X19, K2-X20
X14/X15/X19/X20Robot signal exchange proxy, customer inter-
face connection
F
K4ETHERNET
SWITCH
Ethernet switch connectionG
Q0Q0Power inlet switchH
X0X0Power inlet connectorJ
X17X17IP20 DeviceNet connectorK
X45X45IP20 power outlet connectorL
K7ABB Ability
TM
Connected Services Gateway, with Ability
port (option wired) or antenna connector
(options 3G or WiFi)
M
A2-X23WANWAN portN
A2-X2LANLAN portP
A2-X3MGMTManagement portQ
i
Not available for CRB 15000 controller.
ii
Only available for CRB 15000 controller.
Power inlet switch
Use the power inlet switch to turn on and off power to the controller. It also possible
to restart the controller using the FlexPendant.
Note
When restarting the controller, wait until the LED PC STAT has turned off before
turning on power again.
Continues on next page
Product manual - OmniCore C30 83
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.1 Connectors on the OmniCore C30 controller
Continued