Note/IllustrationAction
xx1900001877
Fasten the assembly with the screws.4
Reconnect all the connectors on as-
sembly of the robot signal exchange
proxy, ethernet extension-seven port
switch (option), ABB ability™ connected
services, and main computer.
5
For the robot signal exchange proxy:
• K2.X8 - A2.X6
• (option): K2.X2 - K4.X8, A2.X1
• K2.X12 - A2.K3.X6, A2.K3.X7
• K2.X10 - A1.X13
• K2.X21 - TempSensor (G3.TEMP)
• K2.X4 - A1.X9
• K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
• K2.X1 - T2.X2
• K2.X17 - G3.X1, G1.X2
• K2.X6, K2.X11 - A1.X2
• K2.X7, K2.X22 - Harn. LV robot
power (X1)
• K2.X9 & X13 - FlexPendant (X4)
For the Ethernet extension switch (op-
tion):
• K2.X2 - K4.X8, A2.X1
• K4.X7 - K5.1.X5
• K4.X6 - A2.X4
For the Connected Services Gateway:
• K7.X1 - K2.X3
i
• K7.X2 - A2.X5
Note
The connector K7.X2 is locked;
grab the connector, push it in to
release it and then remove the
connector.
Continues on next page
132 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.7.6 Installing the fieldbus master
Continued