Parameters 109
174.27 M1 DC input current
range selection
Sets DC input current measurement range.
0 = 200 A
1 = User selection (default is 400 A)
0b0000/
Bit list
b0: M1S1 Input current
range
b1: M1S2 Input current
range
b2: M1S3 Input current
range
b3: M1S4 Input current
range
b4: M1S5 Input current
range
b5: M1S6 Input current
range
b6: M1S7 Input current
range
b7: M1S8 Input current
range
b8: M1S9 Input current
range
b9: M1S10 Input current
range
b10: M1S11 Input
current range
b11: M1S12 Input
current range
b12...b15: Reserved
174.28 M2 DC input current
range selection
Sets DC input current measurement range.
0 = 200 A
1 = User selection (default is 400 A)
0b0000/
Bit list
b0: M2S1 Input current
range
b1: M2S2 Input current
range
b2: M2S3 Input current
range
b3: M2S4 Input current
range
b4: M2S5 Input current
range
b5: M2S6 Input current
range
b6: M2S7 Input current
range
b7: M2S8 Input current
range
b8: M2S9 Input current
range
b9: M2S10 Input current
range
No. Name/Value Description Def/
FbEq16/32