190.12 Phase voltage neg seq Shows negative sequence value of phase voltage. -/ Real
0.00 … 2000.00 V Negative sequence of phase voltage. 1 = 1 V/
100 = 1 V
190.13 Main voltage pos seq Shows positive sequence value of line-to-line voltage. -/ Real
0.00 … 2000.00 V Positive sequence of line-to-line voltage. 1 = 1 V/
100 = 1 V
190.14 Main voltage neg seq Shows negative sequence value of line-to-line voltage. -/ Real
0.00 … 2000.00 V Negative sequence of line-to-line voltage. 1 = 1 V/
100 = 1 V
190.15 Frequency Shows estimated frequency of the measured voltage. -/ Real
0.00 … 100.00 Hz Estimated frequency of measured voltage. 1 = 1 Hz/
100 = 1 Hz
195 HW configuration
Various hardware-related settings.
195.14 Connected modules Shows connected and found modules of parallel
connection (bit field).
This parameter is read-only.
0b0000/
Bit list
b0: Module 1
b1: Module 2
b2: Module 3
b3: Module 4
b4: Module 5
b5: Module 6
b6: Module 7
b7: Module 8
b8: Module 9
b9: Module 10
b10: Module 11
b11: Module 12
b12...b15: Reserved