88 Parameters
b2: Connect
undervoltage
Connect undervoltage is not within limit.
b3: Connect overvoltage Connect overvoltage is not within limit.
b4: Underfrequency 1 Underfrequency 1 is not within limit.
b5: Underfrequency 2 Underfrequency 2 is not within limit.
b6: Overfrequency 1 Overfrequency 1 is not within limit.
b7: Overfrequency 2 Overfrequency 2 is not within limit.
b8: Undervoltage 1 Undervoltage 1 is not within limit.
b9: Undervoltage 2 Undervoltage 2 is not within limit.
b10: Undervoltage 3 Undervoltage 3 is not within limit.
b11: Undervoltage 4 Undervoltage 4 is not within limit.
b12: Overvoltage 1 Overvoltage 1 is not within limit.
b13: Overvoltage 2 Overvoltage 2 is not within limit.
b14: Overvoltage 3 Overvoltage 3 is not within limit.
b15: Overvoltage 4 Overvoltage 4 is not within limit.
135.252 Grid monitoring SW3 Grid monitoring status word 3.
This parameter is read-only.
0x0000/
Bit list
b0: Reserved
b1: Sliding overvoltage Sliding voltage in not within limit
b2: Combinatory limit Combinatory limit is not within limit
b3: Extreme AC
overvoltage
Internal AC overvoltage
b4: RoCoF Rate of change of frequency is too high.
b5: Anti-islanding
underfrequency
Anti-islanding underfrequency is not within limit.
b6: Anti-islanding
overfrequency
Anti-islanding overfrequency is not within limit.
b7: Anti-islanding
undervoltage
Anti-islanding undervoltage is not within limit.
b8: Anti-islanding
overvoltage
Anti-islanding overvoltage is not within limit.
b9: Anti-islanding Anti-islanding signal is too high.
b10: Underfrequency 3 Underfrequency 3 is not within limit.
b11: Underfrequency 4 Underfrequency 4 is not within limit.
b12: Underfrequency 5 Underfrequency 5 is not within limit.
b13: Underfrequency 6 Underfrequency 6 is not within limit.
b14: Overfrequency 3 Overfrequency 3 is not within limit.
b15: Overfrequency 4 Overfrequency 4 is not within limit.
150 FBA
Fieldbus adapter communication configuration.
150.01 FBA A Enable Enables communication between the inverter and
fieldbus adapter A, and specifies the slot the adapter is
installed into.
Option slot 2/
List
Disabled Communication between inverter and fieldbus adapter A
disabled.
0
Option slot 1 Communication between inverter and fieldbus adapter A
enabled. The adapter is in slot 1.
1
No. Name/Value Description Def/
FbEq16/32