Description Type test value Reference
• Shock withstanding test Peak acceleration: 15 g
Duration of the pulse: 11 ms
Number of pulses in each
direction: 3
• Bump test Peak acceleration: 10 g
Duration of the pulse: 16 ms
Number of pulses in each
direction: 1000
Seismic test Class 2 IEC 60255-21-3
• Nominal frequency range 1...35 Hz
• Zero period acceleration Horizontal direction: 2.0 gn
Vertical direction: 1.0 gn
• Number of time histories in
each axis
Single axis sine sweep
Table 210: Environmental tests
Description Type test value Reference
Dry heat test • 96 h at +70°C IEC 60068-2-2 and IEEE
C37.90-2005
Dry cold test • 96 h at -25°C
• 16 h at -40°C
IEC 60068-2-1 and IEEE
C37.90-2005
Damp heat cyclic test • 6 cycles (12 h + 12 h) at
+25...+55°C, humidity
>93%
IEC 60068-2-30
Damp heat steady state test • Temperature 40°C
• Humidity 93%
• Duration 96 h
IEC 60068-2-78 and IEEE
C37.90-2005
Change of temperature test • 5 cycles (3 h + 3 h) at
-25...+55°C
IEC60068-2-14
Storage test • 96 h at -40°C
• 96 h at +85°C
IEC 60068-2-1, IEC 60068-2-2
and IEEE C37.90-2005
Table 211: EMC compliance
Description
Reference
EMC directive 2004/108/IEC
Standard EN 50263 (2000)
EN 60255-26 (2007)
Table 212: RoHS compliance
Description
Complies with RoHS directive 2002/95/EC
1MRS757488 H Section 11
Device and functionality tests
RIO600 297
Installation and Commissioning Manual