Name Values (Range) Unit Step Default Description
Operation03 Disabled
Enabled
- - Disabled Operation On/Off
NomValue03 0.0 - 999999.9 - 0.1 0.0 Nominal value for analog channel 3
UnderTrigOp03 Disabled
Enabled
- - Disabled Use under level trig for analog cha 3 (on) or
not (off)
UnderTrigLe03 0 - 200 % 1 50 Under trigger level for analog cha 3 in % of
signal
OverTrigOp03 Disabled
Enabled
- - Disabled Use over level trig for analog cha 3 (on) or
not (off)
OverTrigLe03 0 - 5000 % 1 200 Overtrigger level for analog cha 3 in % of signal
Operation04 Disabled
Enabled
- - Disabled Operation On/Off
NomValue04 0.0 - 999999.9 - 0.1 0.0 Nominal value for analog channel 4
UnderTrigOp04 Disabled
Enabled
- - Disabled Use under level trig for analog cha 4 (on) or
not (off)
UnderTrigLe04 0 - 200 % 1 50 Under trigger level for analog cha 4 in % of
signal
OverTrigOp04 Disabled
Enabled
- - Disabled Use over level trig for analog cha 4 (on) or
not (off)
OverTrigLe04 0 - 5000 % 1 200 Over trigger level for analog cha 4 in % of signal
Operation05 Disabled
Enabled
- - Disabled Operation On/Off
NomValue05 0.0 - 999999.9 - 0.1 0.0 Nominal value for analog channel 5
UnderTrigOp05 Disabled
Enabled
- - Disabled Use under level trig for analog cha 5 (on) or
not (off)
UnderTrigLe05 0 - 200 % 1 50 Under trigger level for analog cha 5 in % of
signal
OverTrigOp05 Disabled
Enabled
- - Disabled Use over level trig for analog cha 5 (on) or
not (off)
OverTrigLe05 0 - 5000 % 1 200 Over trigger level for analog cha 5 in % of signal
Operation06 Disabled
Enabled
- - Disabled Operation On/Off
NomValue06 0.0 - 999999.9 - 0.1 0.0 Nominal value for analog channel 6
UnderTrigOp06 Disabled
Enabled
- - Disabled Use under level trig for analog cha 6 (on) or
not (off)
UnderTrigLe06 0 - 200 % 1 50 Under trigger level for analog cha 6 in % of
signal
OverTrigOp06 Disabled
Enabled
- - Disabled Use over level trig for analog cha 6 (on) or
not (off)
OverTrigLe06 0 - 5000 % 1 200 Over trigger level for analog cha 6 in % of signal
Operation07 Disabled
Enabled
- - Disabled Operation On/Off
NomValue07 0.0 - 999999.9 - 0.1 0.0 Nominal value for analog channel 7
Table continues on next page
1MRK504116-UUS C Section 3
IED application
789
Application manual