【Auto】 mode
<
Operation
>
By changing Mode: Normal in < Memory>2/3 of [Menu] screen to Mode: Auto with the
▲▼key , and fixing it with
[Set]
key, the following screen appears:
Select to
Mode:Auto
Mode :Auto :Automatic measurement, where the following items are
available.
Interval :Single : Measuring interval setting
Single:The measurement starts with
[Start/Stop
] key and is
terminated at Meas.Time selected.
Repeat :The measurement starts with
[Start/Stop]
key and is
repeated in every Meas.Time selected until
[Start/Stop]
key is pressed.
I/O :External output setting
ON :Outputs data for one second when the data
memory mode is active.
OFF :Default (Data output is disabled)
.
Level :Threshold level is registered.
Samp Time:Sampled at interval equal to Meas.time.
100ms :sampled at interval 100ms (0.1s).
200ms :sampled at interval 200ms (0.2s).
1s :sampled at interval 1s
Meas.Time :is time set with
[Meas.Time]
key (1s~-・・・).
※Select 10s or more in L
Atm5
measurement.
Sta :Registers the starting time for recording (YY/MM/DD HH/MM/SS)
Stp :Registers the stop time for recording (YY/MM/DD HH/MM/SS)
<Record contents of Memory Card(SD Card)>
Samp Time
Style A C Z
200ms
1s
Sound pressure level ― L
C
Lp
A-weighted sound level L
A
― ―
Meas.Time
Time-average sound level ― L
Ceq
Lpeq
Aeq
―
―
AE
CE
PE
aximum sound pressure level
Amax
Cmax
Pmax
Amin
Cmin
Pmin
Percentile sound
pressure level
(L
AN
)
Percentile (5%) sound pressure level
A05
C05
P05
Percentile (10%) sound pressure level
A10
C10
P10
Percentile (50%) sound pressure level
A50
C50
P50
Percentile (90%) sound pressure level
A90
C90
P90
Percentile (95%) sound pressure level
A95
C95
P95
―
Cpeak
peak
Time, when when RSR card is installed
<Memory> 2/3
Mode :Normal
Interval :Single
<Memory> 2/3
Mode :Auto
Interval :Single
I/O :OFF
Level : 65dB
Samp Time
:MeasTime
Sta:08/10/10 18:16:00
Stp:08/10/12 20:16:00