EasyManua.ls Logo

Aeroflex 2023A - Page 143

Aeroflex 2023A
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE OPERATION
5-34
BLANK Blank or unblank display parameters: Carrier Frequency, RF Level,
Modulation Depth and Deviations, and Modulation Frequency
Data type :
None
Allowed suffices : None
Default suffix : None
Examples:
BLANK:ON
BLANK:OFF
BLANK?
Prepares message containing information on the display blanking setting in the
following format:
:BLANK:<state>
where: <state> is program mnemonic indicating whether the blanking is ON
or OFF
Examples:
BLANK:OFF
CONTRAST
Sets the LCD contrast, over a scale of 0 to 255
Data type :
Decimal Numeric Program Data
Allowed suffices :
none
Default suffix :
none
Examples:
CONTRAST 120
CONTRAST?
Prepares message containing information on LCD contrast setting in the
following format:
:CONTRAST <nr1>
Example:
:CONTRAST 78
ELAPSED
:RESET
Reset elapsed operating hours to zero
Data type :
None
Allowed suffices :
None
Default suffix :
None
Example:
ELAPSED:RESET
ELAPSED?
Prepares message containing information on elapsed operating hours since last
reset. Fractional part is in 15 minute intervals (0.25, 0.50, 0.75). Format is as
follows:
<nr2>
Example:
454.50
OPER?
Prepares message containing information on total operating hours. Fractional
part is in 15 minute intervals (0.25, 0.50, 0.75). Format is as follows:
<nr2>
Example:
1453.00

Table of Contents